6.5.4 Duration of Use
Lockers operating in free locker mode can be configured to limit the user to a defined period of use. See section
5.2.1. Free Locker Mode (with or without Duration of Use Function)” for detailed information. The duration of use
function is found here:
Configuration > Operating mode > Free Locker
Select either “Duration” or “Point of time” from the “Use time limit” menu for the type of time limit.
Define the time limit in minutes in the “Time limit (min)” field.
6.5.5 Pre-Lock Personal Locker
The pre-lock function for personal lockers allows the locker to lock automatically when the locker door is pushed
shut, without needing to use a data carrier. The locker can be unlocked again using the data carrier(s) authorized to
use the personal locker. The function is found here:
Configuration > Operating mode > Personal Locker > PreLock Personal Locker
Select / deselect the “PreLock Personal Locker” option to turn the function on / off.
6.5.6 RF Standards
The GAT ECO.Lock 7xxx F/ISO can operate with data carriers that use ISO 15693 and ISO 14443A (MIFARE)
technology.
The default setting for the GAT ECO.Lock 7xxx F/ISO is to operate with ISO 14443A (MIFARE) data carriers.
The setting for the GAT ECO.Lock 7xxx F/ISO to operate with ISO 14443A (MIFARE) data carriers cannot be
changed. The setting for the GAT ECO.Lock 7xxx F/ISO to operate with ISO 15693 data carriers can be adjusted
and is found here:
Configuration > Reader > RF Standards > ISO 15693
Select / deselect the “ISO 15693” option to turn the setting on / off.
6.5.7 Master Cards
Up to 10 master cards can be assigned to the GAT ECO.Lock 7xxx F/ISO to allow the locker to be opened in
special circumstances, e.g., when a user has lost their data carrier. For this functionality, the master cards must be
first assigned to the GAT ECO.Lock 7xxx F/ISO, which is done here:
Configuration > Application > Master cards > Master Card 1 - 10
Enter the number of each master card (data carrier) into the respective fields.
NOTE! The master card numbers must be entered in hexadecimal format.