Testing sensors
You can test sensors one at a time to make sure they are sending strong signals to the panel. You should test the
security system at least once a week.
To perform the sensor test, do the following:
1. Scroll to System tests.
2. Press Enter. The display shows Enter code.
3. Enter your master code with the numbered keys.
4. Press Enter to accept the master code. The display shows Sensor test.
5. Press Enter. The display shows, for example, Trip Sn 1 front door and automatically displays the list
of sensors to be tested. The panel sounds six beeps once a minute while in sensor test mode. See
Table 12.
When you trip a sensor the display shows, for example, Sn 1 packets = 8 front door. You may trip the sensors
in any order. As each sensor is heard from, it is removed from the list of sensors to be tested.
After all sensors have been successfully tested, the display shows Sn test complete, press Status. To terminate
the sensor test, do the following:
1. Press Status. The display shows Sensor test OK.
2. After a few seconds the display shows Sensor test.
3. Press Status repeatedly to exit.
If any of the sensors did not test successfully and you want to terminate the test, press Status. The panel
display will show Sensor test fail or aborted. The display then shows Sensor test. Press Status once to exit the
system test. If a sensor test fails, call your security dealer.
Table 12. How to trip devices for sensor test
Device To trip device
Door/window sensor Open the secured door or window.
Motion sensor Avoid the motion sensor’s view for five minutes, then enter its view.
Shock sensor Tap the glass twice, away from the sensor. Wait at least 30 seconds before testing again.
Smoke sensor Press and hold the test button until the system sounds transmission beeps.
Two-button pendant panic
sensor
Press and hold both buttons simultaneously for three seconds.
Keyfob Press and hold lock and unlock simultaneously for three seconds.
Remote handheld touchpad Press and hold the two emergency buttons simultaneously for three seconds.