EasyManuals Logo

GE Dash 4000 Operator's Manual

GE Dash 4000
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #195 background imageLoading...
Page #195 background image
Maintenance
2000966-386D Dash™ 3000/4000/5000 A-3
Cleaning and disinfecting
Procedure
WARNING
—Disconnect the monitor from AC power before cleaning or
disinfecting its surface.
CAUTION
—Failure to follow these rules may melt, distort or dull the exterior
surface finish, blur lettering on labels or cause equipment failure.
NOTE
For additional information, refer to the How to Reach Us page of the manual for
contact information. Also see the operator’s manuals provided with each
handheld and patient monitoring device to safely clean or disinfect telemetry
transmitters, acquisition modules, patient monitors, ECG cables, and leadwires.
NOTE
Clean the exterior surface on a regular basis in compliance with your institution’s
infection control and biomedical engineering department.
Complete the following procedure to clean the exterior surfaces of this equipment:
1. For cleaning all displays, including touchscreen and standard displays, do the
following:
a. Turn off the power to the touchscreen and standard displays before you start
cleaning the displays.
b. Wipe the exterior with a soft lint-free cloth, lightly moistened with
household glass cleaner.
2. For cleaning the equipment, wipe the exterior with a soft lint-free cloth, using the
following solution as recommended in the APIC Guidelines for Selection and
Use of Disinfectants (1996):
Sodium hypochlorite (5.2% household bleach) minimum 1:500 dilution
(minimum 100 ppm free chlorine) and a maximum 1:10 dilution.
Any sodium hypochlorite wipe product that meets the above guidelines can
be used.
NOTE
Wring excess disinfectant from wipe before using.
NOTE
Any contact of the disinfectant solutions with metal parts may cause
corrosion.
3. Wipe off cleaning solutions with a clean, lightly moistened cloth.

Table of Contents

Other manuals for GE Dash 4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Dash 4000 and is the answer not in the manual?

GE Dash 4000 Specifications

General IconGeneral
Resolution640 x 480 pixels
Power Supply100-240 VAC, 50/60 Hz
ECG3/5/12-lead
IBPUp to 4 channels
Battery BackupYes
CertificationsCE, UL, CSA
Parameters MonitoredECG, SpO2, NIBP, IBP, Temperature, Respiration, Cardiac Output
ConnectivityEthernet, USB, Serial
Display TypeTFT LCD
RecorderIntegrated thermal printer
Battery TypeLithium-ion
Operating Temperature0 to 40°C
Storage Temperature-20 to 60°C
Humidity Range15% to 95% non-condensing
Display Size10.4 inches
Cardiac OutputAvailable

Related product manuals