The dryer control has a service test mode that can be utilized by the service technician in order to test
critical components and to access error codes. This test mode will help the service technician to quickly
identify failed or improperly operating dryer components.
To enter the test mode: To exit the test mode:
With the power connected but the power button off:
1. Press the MY CYCLE button.
2. Press the DELAY START button.
3. Press the MY CYCLE button.
4. Press the DELAY START button.
Upon entering the service mode, the control shall be
in test selection mode and display the list of tests on
the vacuum uorescent display (VFD). Scroll through
the list of tests by using the up or down cursor
arrows. Selection shall be represented by bold text.
Once the desired test is highlighted, press ENTER to
begin the test.
During a test, press POWER to terminate it and go
back to test selection mode.
Press the POWER button 3 times during the test
selection mode.
Note: A dryer left in the test mode will exit the test
mode after a period of 30 minutes.
Service Test Mode
(Continued Next Page)

Other manuals for GE Profile DPVH890EJ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Profile DPVH890EJ and is the answer not in the manual?

GE Profile DPVH890EJ Specifications

General IconGeneral
BrandGE
ModelProfile DPVH890EJ
CategoryDryer
LanguageEnglish

Related product manuals