ADV200 • Parameters List 275
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1 Count 16
2 Count 32
3 Fill 16
4 Fill 32
5 Mdplc 16
6 Mdplc 32
7 Eu
8 Eu float
9 Par 16
10 Par 32
23.4.59 4324 Dig Fieldbus S->M15 INT32 16 0 0 0 ERW FVS
23.4.60 4326 Fieldbus S->M15 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.4.61 4330 Fieldbus S->M16 ipa FBS2MIPA 0 0 20000 RW FVS
23.4.62 4332 Fieldbus S->M16 sys ENUM Not assigned 0 10 RW FVS
0 Not assigned
1 Count 16
2 Count 32
3 Fill 16
4 Fill 32
5 Mdplc 16
6 Mdplc 32
7 Eu
8 Eu float
9 Par 16
10 Par 32
23.4.63 4334 Dig Fieldbus S->M16 INT32 16 0 0 0 ERW FVS
23.4.64 4336 Fieldbus S->M16 mul FLOAT 1.0 1.0 1000.0 ERW FVS
23.5 - COMMUNICATION/WORD COMP
23.5.1 4400 Word bit0 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.2 4402 Word bit1 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.3 4404 Word bit2 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.4 4406 Word bit3 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.5 4408 Word bit4 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.6 4410 Word bit5 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.7 4412 Word bit6 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.8 4414 Word bit7 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.9 4416 Word bit8 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.10 4418 Word bit9 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.11 4420 Word bit10 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.12 4422 Word bit11 src LINK 16 6000 0 16384 ERW FVS
L_DIGSEL1
23.5.13 4424 Word bit12 src LINK 16 6000 0 16384 ERW FVS