EasyManuals Logo

gefran GRM-H 15 User Manual

gefran GRM-H 15
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
819XX_MAN_GRM-H_11-2022_ENG_pag. 53
5.4.4.5. Overheat event counter 2
Acronym App / GF_eXpress menu Attribute Retentive U.M. Default
Description
SH.c2
Counters R
- 0
SSR overheat event counter 2 (not resettable).
The counters are saved in the retentive memory every hour and when the line voltage is switched off.
5.4.4.6. Counter reset
Acronym App / GF_eXpress menu Attribute Retentive U.M. Default
Description
STATUS11
Expert Status Diagnostics
R/W - - 0
Overheat counter 1 reset command.
5.4.4.7. SHORT_CIRCUIT_CURRENT event counter 1
Acronym App / GF_eXpress menu Attribute Retentive U.M. Default
Description
FO.c1
Counters R
- 0
SHORT_CIRCUIT_CURRENT event counter 1 (resettable).
5.4.4.8. SHORT_CIRCUIT_CURRENT event counter 2
Acronym App / GF_eXpress menu Attribute Retentive U.M. Default
Description
FO.c2
Counters R
- 0
SHORT_CIRCUIT_CURRENT event counter 2 (not resettable).
5.4.4.9. Counter reset
Acronym App / GF_eXpress menu Attribute Retentive U.M. Default
Description
STATUS11
Expert Status Diagnostics
R/W - - 0
SHORT_CIRCUIT_CURRENT counter 1 reset command.
Bit Meaning
6 SH.c1 count reset
Bit Meaning
11 FO.c1 count reset

Table of Contents