AVy -HGB
Ch.8 136
Value Access via
Keyp. RS485/Terminal Opt2-A
minmaxFactory BUS//PDC
Opt2-M
Flux P [%] 91 Float 0.00 100.00 S
Ö
R/W - -
FluxI[%]92 Float 0.00 100.00 S
Ö
R/W - -
Voltage P [%]1022 Float 0.00 100.00 15.00
Ö
R/W - -
Voltage I[%]902 Float 0.
00 100.00 4.00
Ö
R/W - -
Speed P base [A/rpm]93 Float 0.001 99.999 S
Ö
R/Z - -
Speed I base[A/rpm×ms] 94 Float 0.001 99.999 S
Ö
R/Z - -
Current P base [V/A] 95 Float 0.1 99999.9 S
Ö
R/Z - -
Current I base [V/A×ms] 96 Float 0.1 9999.9 S
Ö
R/Z - -
Flux P base [A/Vs] 97 Float 0.1 9999.9 S
Ö
R/Z - -
FluxIbase [A/Vs×ms] 98 Float 0.01 999.99 S
Ö
R/Z - -
Voltage P base [Vs/V] 1023
Float 0.00001 9.99999 S
Ö
R/W - -
Voltage I base [Vs/V x s]903 Float 0.00001 9.99999 S
Ö
R/W - -
Speed P in use [%] 99 Float 0.00 100.00 S
Ö
R--
Speed Iin use [%]100 Float 0.00 100.00 S
Ö
R--
Maincommands 252 U16 0 1Terminals (0)
Ö
R/Z - -
Terminals 0
Digital 1
Control m
ode 253 U16 0 1Local (0)
Ö
R/Z - -
Local 0
Bus 1
Speed base value [FF] 45U32*** 1 16383 1500
Ö
R/Z - R
Regulationmode 321 U16 03V/f control (3)
Ö
R/Z - -
Sensorless vect 0
Self-tuning 1
Field oriented 2
V/f control 3
Full load curr [A] 179 Float 0.10 999.00 S
Ö
R/Z - -
Flt_1
00_mf 303 I16 032767 S -R - R
Magn ramp time [s]675 Float 0.01 5.00 1.00
Ö
R/Z - -
Magn boost curr [%]413U16 10 136 30
Ö
R/Z - -
Ok relay funct 412 I16 0 1 Drive healthy (0)
Ö
R/Z - -
Drive healthy 0
Ready to start 1
Switching freq 240U16 SS S
Ö
R/Z - -
4 KHz 0
8 KHz 1
16 KHz 2
2 KHz
3
Qstpoptcode 713 I16 -2 -1 Ramp stop (1)
Ö
R/Z - -
Ramp stop 1
DC braking 2
Npar displayed 1291 U16 0 65535 0
Ö
R/W - -
Pword 1: 85 I32 00000 99999 Disabled (0)
Ö
W--
Enabled 1
Disabled 0
Speed fbk sel 414 U16 0 1Enc.1 (1)
Ö
R/Z ID R/W
Encoder 1
1H
Encoder 2 0 L
Encoder 1 type 415 I16 0 1 Digital (1)
Ö
R/Z - -
Sinusoidal 0
Digital 1
Encoder 1pulses 416 Float*600 9999 1024
Ö
R/Z - R
REG PARAMETERS \Percent values \Flux regulator
Parameter No Format
REG PARAMETERS \Base values \Voltage reg
CO
NFIGURATION
REG PARAMETERS \In use values
CONFIGURATION\Motor spd fbk
REG PARAMETERS \Percent values \Voltage reg
REG PARAMETERS \Base values \ Speed regulator
REG PARAMETERS \Base values \Current reg
REG PARAMETERS \Base values \Flux regulator

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive AVy Series and is the answer not in the manual?

gefran SIEIDrive AVy Series Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive AVy Series
CategoryController
LanguageEnglish

Related product manuals