C-9
Command Sets
Function Command
Selecting Character Sets
See Figure “Designating and Invoking Character Sets” later in this section.
Mnemonic Function Command Remarks
ASCEF Announce Subset ESC SP L ASCII in G0 and GL.
of Code Extension ISO Latin-1 in G1 and GR.
Facilities ESC SP M Same as ESC SP L
ESC SP N ASCII in G0 and GL.
DECAUPSS Assign User DCS Ps ! u Ps = 0: 94-char. set
Preference D . . . D ST Ps = 1: 96-char. set
Supplemental Set D . . . D: SCS designating sequence.
ISO Latin 9 DCS 1 ! u b ST ST = 09/12 or Esc\
SS2 Single Shift 2 C1 Control Take the next character from G2
Code
7-bit environment
: ESC N
SS3 Single Shift 3 C1 Control Take the next character from G3
Code
7-bit environment
: ESC O
LS0 Locking Shift 0 SI Invoke G0 into GL
(or Shift In)
LS1 Locking Shift 1 SO Invoke G1 into GL
(or Shift Out)
LS2 Locking Shift 2 ESC n Incoke G2 into GL
LS3 Locking Shift 3 ESC o Invoke G3 into GL
LS1R Locking Shift 1 Right ESC ~ Invoke G1 into GR
LS2R Locking Shift 1 Right ESC } Invoke G2 into GR
LS3R Locking Shift 1 Right ESC | Invoke G3 into GR
SCS Select Character Set ESC I
1
I
2
F I
1
= “(”: Invoke 94-char. set into G0
I
1
= “)”: Invoke 94-char. set into G1
I
1
= “*”: Invoke 94-char. set into G2
I
1
= “+”: Invoke 94-char. set into G3
I
1
= “-”: Invoke 96-char. set into G1
I
1
= “.”: Invoke 96-char. set into G2
I
1
= “/”: Invoke 96-char. set into G3
I
2
F = final characters from
“SCS Final Characters” later in this
section