Total Station Manual
32
HD: Ground distance
2. Ground distance
HD=HDg/(Grid factor)
Note:
1. The enter range of the scale factor: 0.99~1.01,the default value is 1.0.
2. The enter range of the average height above sea level: -9999.9999~9999.9999. The
average altitude retained after the decimal point one, the default value is0.
Steps Key Display
ƻ
1
After entering to the
interface of EDM
Setting,press the key of [F4]
to enter the second page of
soft key, then press te key of
[F1](Grid) to set the Grid
Scale.
[F4]
[F1]
ƻ
2 Interface displays the
current setting.Enter the
values of Scale and Altitude
then press the key of
[ENT].Program calculates the
Grid Scale and displays it in
the interface.If you want to set
all enter area to 0,you can set
the key of [F1] (Reset).
[ENT]
ƻ
3 After finished setting,
press [F4](OK) to save settins
and back to previous
menu.Then press the key of
[F3](OK) to save the setting of
EDM and back to the function
of measurement.
[F4]