Total Station Manual
85
ƻ
2
Press direction key and
move the cursor to input prism
height item. Input the prism
height and then press [ENT] to
confirm.
Ę
+
Input
prism
height
+
[ENT]
ƻ
3 Aim at the prism. Press
[F2](DIST) to start measuring
and calculate the differences
between measured point and
stakeout point.
[F2]
ƻ
4 Move the prism along the
East direction to make the
value of
Ƹ
Y/E equal 0m.
Ƹ
Y/E is positive: The
stakeout point is in the right
side of measured point. Move
the prism to right.
Ƹ
Y/E is negative: The
stakeout point is in the left
side of measured point. Move
the prism to left.
ƻ
5 Move the prism along the
North direction to make the
value of
Ƹ
X/N equal 0m.
Ƹ
X/N is positive: The
stakeout point is farther than
the measured point. Move the
prism far away the station.
Ƹ
X/N is negative: It needs to
move the prism close to the
station.