Zoom80 | 152Technical Data
Humidity
Reflectors
There are no special prisms required for Aim360 or for Scout360.
Type Protection
Instrument Max 95 % non condensing
The effects of condensation are to be effectively coun-
teracted by periodically drying out the instrument.
Type Additive Constant
[mm]
Aim36
0
Scout360
Circular prism 0.0 yes yes
Mini prism +17.5 yes yes
Mini 0 0 yes yes
360° prism +23.1 yes yes
360° Mini prism +30.0 yes not recommended
Reflective tape +34.4 yes no
Reflectorless +34.4 no no