Zoom80 | 92Check & Adjust
3. TOOLS Tilting-Axis Adjustment I
Aim the telescope accurately at a
target at about 100 m distance or less
if not possible. The target must be
positioned at least 27°/30 gon above
or beneath the horizontal plane.
The procedure can be started in any
telescope face.
Step Description
V=90°
+ 27°
- 27°