Technical characteristics Bedienungsanleitung MSA 4
30
8 Technical characteristics
Mains voltage/frequency
230 V (190V – 265V) 50 / 60 Hz
Suggested power generators
3 kW
Welding technique
Voltage controlled
Fusion voltage
8 – 42 (48) V
Operating temperature
-20°C – +50°C
Internal temperature
-20°C – +70°C
Temperature sensor resolution
± 1°C
Fittings range
Ø16mm – Ø1200mm(*)
*
Consult your Georg Fischer sales
representative before usage out of this
dimension range
Fusion data input mode
Bar code, manual
Capacity of internal memory
5000 protocols
USB Port
Type A
Barcode reader port
USB
Protection factor
IP 65
Dimensions
280x280x420 mm (max)
Weight
12.5 kg
8.1 Standards
ISO 12176-2;
ISO 12176-3;
ISO 12176-4;
UNI 10566 (2009);
EN 60335-1 (Safety);
EN 61000-6-2 (EMC);
EN 61000-6-4 and others (EMC).