EasyManua.ls Logo

GMV GLT 81-21 - Page 22

Default Icon
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENG
4.0
10991793EN
-
19.10.2022
GLT
Ω
L
IFT
O
PERATION AND
M
AINTENANCE
M
ANUAL
Page | 22
DESCRIPTION OF COLLECTIVE DOWN OPERATION
The collective down operation phases are described below.
1. The user presses the call button on the landing to call the lift, whether it is in the “free” or “in use” status.
2. The electrical cabinet is designed to store and fulfil all calls accepted from the landing while the lift is moving
to the main floor.
3. The lift executes the call made and if it is moving towards the main floor, it answers any calls made from the
intermediate floors.
4. When the lift arrives at the floor from which a call was made, if the load limit has not been reached, the
doors automatically open to allow entry into the car.
5. The lift remains available for passengers to press the button on the car push-button panel for the desired
destination floor.
6. The doors close and the car departs, in the same direction as before, towards the nearest destination floor or
nearest floor from where a call was accepted.
7. If the desired destination floor is in the opposite direction to the direction of travel, the lift will reach the
main or top/bottom floor and then fulfil the request.
8. When the lift reaches the required floor, the doors automatically open to allow passengers to exit the car.
PUSH-BUTTON PANELS WITH AUTOMATIC LANDING DOORS
STD
LAW 13 (ITALY)
EN 81-70