EXIT SEQUENCE
STEP
ACTION NOTES
1
Bring the car to the next floor above the pit by traditional call.
Visible:GREEN light
2
Press the emergency stop (red button).
Visible:RED light
3
Turn the selector switch on the maintenance push-button panel to
“automatic operation”.
Visible:RED light
4
Lower the “CAR” pedestal from the vertical position to the horizontal
position.
Visible:RED light
5
Lower the “COUNTERWEIGHTpedestal from the vertical position to the
horizontal position.
Visible:RED light
6
Detach the ladder from its storage housing and place it ready to climb out
of the pit.
Visible:RED light
7
Open the landing door to the pit by pulling the lock release cable on the
door.
Visible:RED light
8
Climb out of the pit up to the entrance landing.
Visible:RED light
9
Put the ladder back into its storage housing.
Visible:RED light
10
Release the emergency stop (red button).
Visible:RED light
11
Close the landing door.
Visible:RED light
12
Turn the key on the “RESET” switch outside the landing to reset the
electrical panel functions (buzzer).
Visible: no light
13
The lift is back in service (floor call buttons are not lit).
Visible: no light
IMPORTANT!
When exiting the pit and/or the car roof, the maintenance technician is advised to ensure that no
equipment or tools have been left behind that can impair smooth operation of the lift or even