7 ) Reset the speed governor by pressing on the control panel the button " STL 2 " .
8 ) CAUTION - For the installation with Coated Steel Ropes, proceed to unload weight from the cabin and
start the operation in step " 9 ". CAUTION: immediately stop the unblocking operation as soon as the ropes
begin to slip on the traction sheave ( from the control panel implement the by-pass procedure with the
doors open and visually check the slip from the top end plane ) .
9 ) Using the electric emergency device " QBME " in the operating panel , turn the selector switch to "
electric emergency maneuver " and move the car cabin up in maintenance .
If the safety gear have not released when the drive has reached the maximum current delivery limit ,
proceed to unload weight from the cabin and repeat the operation in step " 9 " .
10 ) Verify the correct mechanical ( visually ) and electrical unlocking of the safety gear ( LEDs " 8 " and " 10
" on the " STK1R " board in the switchboard light up )
11 ) Check the performance of the safety gear by accessing the shaft from the pit or cabin roof , checking
the simultaneity of safety gear deployment according to the track traveled on the guides .
12 ) Restore the rail surface affected by safety gear deployment to safeguard the skids and transit noise .
13 ) On the electric emergency button " QBME " in the operating panel , return the selector switch to "
normal operation " .