MDE-LEDI-NETWORK-TDS-4099V3.0
63
POLAR PULSE
Alarm: alarm indicator (power, open serial circuit, parallel short-circuit).
Output time: displaying the time sent to impulsion clocks.
Period: impulsion selections every 30 or 60 seconds.
Impulsion Duration: adjustment of the impulsion duration in quarters of a second.
12/24 Hours Format: allows the selection of the time format distributed to the
standard 0 to 23 hours (digital clocks|) or to the standard 1 to 12 hours (analogue
clocks).
Relative Correction: allows you to add or subtract a number of impulses from 1 to 9
without modifying the time sent (example of application: polarity adjustment).
Absolute Correction: adjustment of the distributed time on impulsion clocks.
Start-up procedure:
Check the box Disable the output card and then press Save Settings” to stop
pulse from being generated.
Connect the clock line to the back slot.
Set the offset and the DST policy.
Set the period, pulse duration and format.
Note the hour and minute displayed by the receiver clocks.