MDE-LEDI-NETWORK-TDS-4099V3.0
8.5. SUPERVISION PROTOCOLS
8.5.1. Syslog messages catalogue
The table below shows Syslog messages sent by the device.
- A new configuration has been defined.
- A new configuration has been defined through the front panel.
- A new configuration has been defined through the Telnet interface.
- A new configuration has been defined in the \"Alarms\" Webpage.
- A new configuration has been defined in the \"Inputs\" Webpage.
- A new configuration has been defined in the \"Interface\" Webpage.
- A new configuration has been defined in the \"Network\" Webpage.
- A new configuration has been defined in the \"NTP\" Webpage
- A new configuration has been defined in the \"PTP\" Webpage.
- A new configuration has been defined in the \"Output\" Webpage.
- A new configuration has been defined in the \"SNMP\" Webpage.
- System has restarted, reason: Reset / Power Failure.
- System has restarted, reason: User Request with Configuration Changes.
- System has restarted, reason: User Request without Configuration Changes.
- System has restarted, reason: Automatic for Configuration Changes.
- System has restarted, reason: Firmware Update.
- A Web interface has been accessed.
- A SNMP trap has been sent, with ID 4: NTP client software start learning environment&network
- A SNMP trap has been sent, with ID 5: NTP client software entering normal behavior
- A SNMP trap has been sent, with ID 6: Not enough replies of current synchronization server
- A SNMP trap has been sent, with ID 7: New server elected for synchronization
- A SNMP trap has been sent, with ID 8: NTP server software is starting
- A SNMP trap has been sent, with ID 9: The hardware is synchronized on its time reference
- A SNMP trap has been sent, with ID 10: The hardware is not synchronized on its time reference
- A SNMP trap has been sent, with ID 11: NTP server locked by the user
- A SNMP trap has been sent, with ID 13: NTP server software is rescaling on its PPS source
- A SNMP trap has been sent, with ID 14: NTP server software is rescaled on its PPS source
- A SNMP trap has been sent, with ID 15: Failure: no more time code and the time base has no more autonomy
- A SNMP trap has been sent, with ID 16: Warning: no time code. The time base has less than 3 minutes of
autonomy
- A SNMP trap has been sent, with ID 17: The hardware has never been externally synchronized
- A SNMP trap has been sent, with ID 19: Power supply is running again
- A SNMP trap has been sent, with ID 20: Input 1 is no more selectable
- A SNMP trap has been sent, with ID 21: Input 2 is no more selectable
- A SNMP trap has been sent, with ID 22: Input 1 is selectable
- A SNMP trap has been sent, with ID 23: Input 2 is selectable
- An error occurred with the SD-Card.
- Ethernet link connection.
- Ethernet link error. Check the cable.
- NTP Client with MAC address <MAC> from IPvX address <IP> has not requested any synchronization for
<duration> hour(s).