50 GMC-I Messtechnik GmbH
Ambient Conditions
Accuracy 0 ... + 40C
Operation –10
C ... +50C
Storage –20 C ... +60 C
(without rechargeable batteries)
Relative Humidity
Max. 75%, no condensation allowed
Elevation Max. 2000 m
Mechanical Design
Display
Multiple display with dot matrix,
128 x 128 pixels
Dimensions W x L x D = 260 x 330 x 90 mm
(without measurement cables)
Weight Approx. 2.3 kg with rechargeable
batteries
Protection Housing: IP 40, test probe: IP 40
per DIN VDE 0470, part 1 / EN 60529
Extract from table on the meaning of IP codes
Data Interface
Type USB slave for PC connection
Type
RS 232 for barcode and RFID readers
IP XY
(1
st
char. X)
Protection against foreign
object entry
IP XY
(2
nd
char. Y)
Protection against the
penetration of water
0 not protected 0 not protected
1 50.0 mm
1 vertically falling drops
2 12.5 mm
2 dripping at angle of 15
3 2.5 mm
3 spraying water
4 1.0 mm
4 splashing water

Table of Contents

Other manuals for Gossen MetraWatt PROFITEST MBASE MTECH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gossen MetraWatt PROFITEST MBASE MTECH and is the answer not in the manual?

Gossen MetraWatt PROFITEST MBASE MTECH Specifications

General IconGeneral
BrandGossen MetraWatt
ModelPROFITEST MBASE MTECH
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals