EasyManuals Logo

Grace Q'nique 16X Elite User Manual

Grace Q'nique 16X Elite
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
90
Parts & Tools Needed:
Instructions
Timing your machine aligns the needle and hook assembly so that they are in the correct places
during the creation of a stitch. Improper timing can result in damage to the machine and needle, or
make sewing impossible. Please consult with a Grace Company support technician before attempting
to adjust the timing on your machine.
Please speak to a Grace Company
support technician before
attempting these instructions.
Part Four | Repairs and Diagnostics
1. Power o the machine and raise the needle
to the highest position using the hand
wheel.
Hand Wheel
1
1. Remove the needle plate (see page 78).
2. Remove the bobbin case from the hook
assembly (see page 28).
2
3
1. Look into the machine’s timing cut-out and
turn the hand wheel. The hook assembly
will rotate.
Timing
Cut-out
Hook
Assembly
4
Flat-head Screwdriver
Tools Box
2 mm
T-handle Allen
Wrench 2 mm
Tools Box
Timing Spacer Tool
Tools Box
Timing the Machine