Operation
28 3B0070C
4. Operate until the pump runs steady and
flushing fluid appears clear.
5. Turn pressure control to OFF.
6. Stop triggering gun.
7. Raise suction tube above flushing fluid.
8. While triggering gun into flushing pail,
turn pressure control to Turboclean to
purge fluid from hose.
9. Engage trigger lock.
10. Turn pressure control knob to OFF and
turn ON/OFF switch to OFF position.
Disconnect power to sprayer.
11. Remove Spray Tip and Spray Tip Guard
from Spray Gun.
12. Remove filter from gun and sprayer if
installed. Clean and inspect. Install filter.
See separate gun manual.
13. If flushing with water, flush again with
Pump Armor to leave a protective
coating to prevent freezing or corrosion.
14. Wipe sprayer, hose and gun with a rag
soaked in water or mineral spirits.