Startup
10 3A4399A
Startup
1. Perform Pressure Relief Procedure, page 8.
2. Turn pressure control to lowest pressure.
3. Turn power ON.
4. Increase pressure 1/2 turn to start motor and allow
fluid to circulate through drain tube for 15 seconds;
turn pressure down.
5. Turn prime valve forward to SPRAY position. Disen-
gage trigger lock.
Trigger Locked (no spray) Trigger Unlocked (spray)
6. Hold gun against grounded metal flushing pail. Trig-
ger gun and increase fluid pressure 1/2 turn. Flush
1 minute.
7. Inspect for leaks. If leaks occur, perform Pressure
Relief Procedure, page 8. Tighten fittings. Perform
Startup, steps 1 - 5. If no leaks, proceed to step 7.
8. Place pump in paint pail.
9. Trigger gun again into flushing pail until paint
appears. Move gun to paint pail and trigger for 20
seconds.
10. Engage trigger lock. Assemble tip and guard, see
instructions on next page.
ti13670b
ti4266b
1/2
15sec.
High-pressure spray is able to inject toxins into the
body and cause serious bodily injury. Do not stop
leaks with hand or rag.
ti22949a
ti18244b
ti18248a