ProGuard
14 3A4399A
ProGuard
This sprayer protects itself against high and low voltage.
If the sprayer is plugged into a power source that is too
low or too high the sprayer will stop operating.
One of three error codes will be displayed:
Error
Code
Definition
Multiple incoming voltage surges
detected - unplug sprayer and
locate good voltage supply to
prevent damage to electronics.
Typical cause of this error is plugging
into a circuit that is higher than the
rated voltage of the sprayer. Find a
circuit that supplies the correct
voltage.
Incoming voltage too low for
sprayer operation - unplug sprayer
and locate good voltage supply to
prevent damage to electronics.
Typical cause of this error is other
equipment on the same circuit or
generator frequently turning on/off
under load. Find a circuit that is
dedicated to the sprayer.
Sprayer plugged into wrong
voltage - unplug sprayer and
locate correct voltage supply.
Typical cause of this error is a GFCI
box that is wired for the wrong
voltage (240V vs. 120V). No damage
has occurred to the sprayer. Find a
circuit with the correct voltage and
the sprayer will run correctly.