Spray Tip Charts
3A8099A 51
Table 1: AXM and GG4 Spray Tip Matrix Table
Orifice
Size
in. (mm)
* Fluid Output
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
at 600 psi
(4.1 MPa,
41 bar)
at 1000 psi
(7.0 MPa,
70 bar)
2 to 4
(75)
4 to 6
(150)
6 to 8
(200)
8 to 10
(250)
10 to 12
(300)
12 to 14
(350)
14 to 16
(400)
16 to 18
(450)
18 to 20
(500)
†0.007
(0.178)
4.0 (0.1) 5.2 (0.15) ~107 207 307
†0.009
(0.229)
7.0 (0.2) 9.1 (0.27) 109 209 309 409 509 ~609
†0.011
(0.279)
9.5 (0.28) 12.5 (0.37) 111 211 311 411 511 611 711
0.013
(0.330)
12.0
(0.35)
16.0 (0.47) ~113 213 313 413 513 613 713
0.015
(0.381)
16.0
(0.47)
21.0 (0.62) 215 315 415 515 615 715 815
0.017
(0.432)
20.0
(0.59)
26.5 (0.78) 217 317 417 517 617 717 817 917
0.019
(0.483)
28.0 (0.8) 36.3 (1.09) 219 319 419 519 619 719 819 919
0.021
(0.533)
35.0 (1.0) 45.4 (1.36) 321 421 521 621 721 821 921
‡0.023
(0.584)
40.0 (1.2) 51.9 (1.56) 423 523 623 723 923
‡0.025
(0.635)
50.0 (1.5) 64.8 (1.94) 425 625 725 825
‡0.027
(0.686)
58.5 (1.7) 75.8 (2.27) 527 627 827
‡0.029
(0.737)
68.0 (1.9) 88.2 (2.65) 629
‡0.031
(0.787)
78.0 (2.2) 101.1
(3.03)
431 631
‡0.033
(0.838)
88.0 (2.5) 114.1
(3.42)
633
‡0.035
(0.889)
98.0 (2.8) 127.1
(3.81)
435
‡0.037
(0.940)
108.0
(3.1)
140.0
(4.20)
737
‡0.039
(0.991)
118.0
(3.4)
153.0
(4.59)
539 639 839
*Tips are tested in water.
Measured with NO airflow. Air assist will tend to reduce pattern lengths by 1 in. to 2 in.
‡Do not use these tips with PerformAA 15 gun models.
†150 mesh tip filter included.
~AXM tips only.
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT) where QT = fluid
output (fl oz/min) from the above table for the selected orifice size.