Table 7: Basic Settings Page
Configures user level password. Case sensitive and max. Length of 25
characters.
Confirm End User Password
Re-enter the end user password to confirm change user password on web
GUI to avoid typo or mistakes.
Configures viewer level password. Case sensitive and max.
Length of 25 characters.
Re-enter the viewer password to confirm change viewer password on web
GUI to avoid typo or mistakes.
Configure timer to logout web session during idle. Default is 10 min.
Range is 2-60 min.
Configure attempt limit before lockout. Default is 5. Range is 1-10.
If login attempt failed 5 times, login would be locked out for the time length.
(Default 15 mins. Range 1-15 min).
Allows users to choose the Web Access Mode between “HTTPS” and “HTTP”.
If “HTTPS” is selected, web UI will be accessed using HTTPS. Default is
“HTTP”.
Customizes HTTP port used to access the HT813 web UI. Default is 80.
Customizes HTTPS port used to access the HT812/HT814 web UI. Default
is 443.
Enables/disables the SSH access. Default is No (enabled).
Allows users to self-configure SSH Port number.
By default, the port number is 22.
Configures SSH session timeout. [0 – 86400] seconds; Default is 0.