Section 7: Touchscreen Display Operation and Settings Page 29
Circuit 2
Circuit Support
Circuit Name Upstairs Rads
Circuit type Radiators
Pump Only
Circuit stop from preset temp
Heating circuit
Figure 7-13: Edit Circuit 2 settings
Tap the < button to navigate backwards to the home screen.
Irrespective of whether pipe sensors are used or not, the space
heating performance can be adjusted based on user comfort
levels using either the Smart controller or via ecoNET24. (Refer to
Section 6.3.2 for Heating curve adjustment guidance)
7.9 USER SETTINGS MENU
User settings can be accessed via the settings menu from the
touchscreen display. (Refer to Figure and Table 7-1 and Figure
7-14).
User settings
04.10.2024
100
100%
Time
Date
Panel address
Language
Parental lock
Screen brightness
Figure 7-14: User settings menu
Time - Time will synchronise with paired thermostats.
Date
Panel Address
Language - Menu language selection.
Parental Lock - The lock will activate after 5 minutes of
inactivity. Unlocking the screen is possible after pressing
down the screen for 5 seconds.
Screen Brightness
Screen saver - Choose screen saver display: None,
Empty, Time, Time and Temps.
Time to screen saver on
Brightness in screen saver.
Alarm sound - Enable/Disable Alarm sounds.
Key sound - Enable/Disable Key sounds.
Panel temperature correction.
! NOTE !
The temperature in the room should be measured with an
additional temperature sensor and the di󰀨erence between
this measurement and the temperature value displayed by
the Touchscreen display should be entered into the value
of this parameter.
Tapping the radio icon symbol (Refer to Figure 7-14):
ecoNET conguration wizard - Wizard conguration of the
Wi-Fi Hub.
ecoNET status - LAN - connection status of Wi-Fi and
ecoNET web services
Wi-Fi settings - conguration of connection with Wi-Fi Hub.
Connection of Wi-Fi and its conguration is described in this
manual. Parameters that should be set by the user: SSID,
Security type and network access password.
Tapping the
i symbol (Refer to Figure 7-14):
Displays diagnostic information about the operation of the
controller, Alarms list, Firmware version and updating (e.g.,
serial number) UID and ISM .
7.10 STORED SYSTEM SETTINGS
The Grant Aerona Smart controller can store and recall a default
system setting scheme within its memory.
Once the system has been installed and commissioned the
applied settings (including demand schedules and Legionella
protection) can be stored within the Grant Aerona Smart controller.
This can be recalled if a setting is perhaps inadvertently changed
causing issues with the system.
7.10.1 SAVE A SYSTEM DEFAULT
To store the currently set system as a default you will need to:
1. Tap the Settings menu and tap 'Service settings'. Input
the relevant password on the keypad and tap enter.
(Password: 0000 - Refer to Section 8).
2. Tap 'Installation controller'.
3. Swipe the screen to scroll down to the bottom and tap
'Default settings'.
4. Tap 'Save current settings as default'.
7.10.2 RESTORE SYSTEM DEFAULT
To restore the currently saved default to the Smart Controller:
1. Tap the Settings menu and tap 'Service settings'. Input
the relevant password on the keypad and tap enter.
(Password: 0000 - Refer to Section 8).
2. Tap 'Installation controller'.
3. Swipe the screen to scroll down to the bottom and tap
'Default settings'.
4. Tap 'Restore default'.
Any paired thermostats will need to be re-paired after a system
default has been restored. The memory will clear if unpowered for
an extended period of time.