Section 16: Product Fiche - HPID16 Page 71
Models: Outdoor Unit: Aerona³ HPID16
Indoor Unit: None
Air-to-water heat pump Yes
Brine-to-water heat pump No
Low temperature heat pump No
Equipped with a supplementary heater No
Heat Pump Combination Heater No
Parameters shall be declared for Medium temperature applications
Parameters shall be declared for Average climate conditions
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output (*) Prated 11 kW Seasonal space heat energy efficiency ƞs 126 %
Declared capacity for heating for part load at indoor temperature 20°C and
outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -10°C Pdh 11.0 kW Tj = -10°C COPd 1.60
Degradation co-efficient (**) Cdh 0.99 -
Tj = -7°C Pdh 9.05 kW Tj = -7°C COPd 1.81
Degradation co-efficient (**) Chd 0.99 -
Tj = +2°C Pdh 6.05 kW Tj = +2°C COPd 3.26
Degradation co-efficient (**) Cdh 0.99 -
Tj = +7°C Pdh 3.9 kW Tj = +7°C COPd 4.58
Degradation co-efficient (**) Cdh 0.99 -
Tj = +12°C Pdh 4.50 kW Tj = +12°C COPd 5.70
Degradation co-efficient (**) Cdh 0.99 -
Tj = bivalent temperature Pdh 11.0 kW Tj = bivalent temperature COPd 1.60
Tj = operation limit temperature Pdh 11.0 kW Tj = operation limit temperature COPd 1.60
Tj = -15°C (if TOL < -20°C) Pdh - kW Tj = -15°C (if TOL < -20°C) COPd -
Bivalent temperature Tbiv -10 Operation limit temperature TOL -10 °C
Heating water operating limit temperature WTOL 60 °C
Power consumption in modes other than active mode Supplementary heater
Off Mode P
OFF 0.01 kW Rate heat output P
sup
0.40 kW
Thermostat off mode P
TO 0.04 kW
Standy mode P
SB 0.01 kW Type of energy input
Crankcase heater mode P
CK 0.00 kW
Other items
Capacity control Variable Rated airflow rate, outdoors - 4464 m
3
/h
Sound power level
indoor/outdoor
L
WA 42/63 dBA
Annual energy consumption Q
HE 6996 kWh
For heat pump combination heater Water heating energy efficiency ƞwh - %
Declared heat load profile - - -
Daily electricity consumption Qelec - kW/h
Annual electricity consumption AEC - kW/h
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating.
Pdesignh, and the rated heat output of a supplementary Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Version 1.1 - June 2017