98
LMIT Parameter Options Description
Scan Lists
On or Off for Scan
Lists 1-22
Sets membership in Scan Lists. Use
3 4
keys to scroll through Scan
Lists. Use SEL key to toggle Scan
List membership. A “
*
” next to the
Scan List number indicates that the
object is mapped to that Scan List.
FrLo
Any supported fre-
quency in MHz
A frequency that will be used as the
lower limit for the limit search range
FrHi
Any supported fre-
quency in MHz
A frequency that will be used as the
upper limit for the limit search range
Tag Alpha-numeric text
The alphanumeric display name for
the LMIT search. Use the standard
text entry method or QTXT to name
the object.
L/Out On or Off
Permanent lockout for the LMIT
channel. Also accessed by pressing
FUNC L/OUT while the scanner is
stopped on the LMIT object.
LED Mode Solid or Flash
Controls whether the ALERT LED
flashes or remains on solid when the
ALERT LED is used.
LED Color 0-7
Sets LED color to 0-7 as defined in
the GLOB menu. By default, 0=LED
Off, 1=Red, 2=Yellow, 3=Green,
4=C y a n , 5 = B lue, 6= M a gent a ,
7=White.
Latch LED On or Off
Normally the ALERT LED is active
only while the object is receiving a
transmission. When Latch is on, the
ALERT LED will remain lit after the
transmission is complete, unless
overridden by a subsequent object
that is also using the ALERT LED.
Backlight On, Off or Flash
Controls whether the backlight
should be on, off or flashing while the
object is active.