Alarm
None, Chirp, Hi-
Lo, Al e r t, Ri n g ,
2-Chirp, Fast Hi-
Lo, DTMF#
Sets the Audible Alarm for the LMIT
object. When an Audible Alarm is
selected, the selected alarm will play
anytime the scanner stops for activity
on the LMIT object while scanning.
Fav Yes or No
When Yes, the LMIT object is a mem-
ber of the Favorites Scan List.
EXPERT BELOW
Modulation AM, FM, Auto
Modulation setting for the LMIT
search. In most cases Auto will work
fine. Use AM to override and force
AM modulation, FM to force FM mod-
ulation,
Atten On or Off
When on, applies 20 dB of attenua-
tion to all hits received on the LMIT
search. Useful in areas where inter-
ference from nearby strong signals is
present.
Delay On or Off
Controls whether a Delay is used to
wait for reply traffic after a transmis-
sion is received during the LMIT
search.
Delay Time 1-200
Sets the amount of time (in 100 mil-
lisecond intervals) for the wait for
reply delay if Delay is On, e.g., 20=2
seconds.
Zeromatic On or Off
When on, enhances the scanner’s
ability to lock on to the actual center
frequency of a search hit instead of
an adjacent frequency.
Search Dir Up or Down
Sets search direction used when
LMIT object is active.
Hit Count Numeric value
Increments each time a transmission
is received on the SWPR object. Glo-
bal “Hit Counts” must be set to ON.
Press the
Dflt