Water Monitoring System
Ver.5.0.1 – Revision August 2022 Page 65 of 111
Trouble
Possible Cause
Action
Air introduction in the
suction connections
Reduce speed and reconsider
application.
Check connections and accessories for
air tightness.
Vibrations on pumps and
pipelines
The pipes are not correctly
fastened
Pump speed too high
Insufficient nominal width
of the pipes
Pump base plate loose
Fasten pipes correctly (e.g. wall
brackets).
Reduce pump speed
Increase nominal width.
Fasten base plate
Hose pump: Reduced
operational lifetime of
the hoses
Chemical exposure
Wrong pump rotation
direction
High pump speed
High conveying temperature
High operating pressure
Pump cavitation
Abnormal elevation of
temperature
Unsuitable lubricant
Insufficient lubrication
Check the compatibility of the hose
with the liquid being conveyed, the
cleaning fluid and the lubricant. If in
doubt always consult the
manufacturer.
Inlet must be at the top connection
and outlet must be at the bottom
connection.
Reduce pump speed
Reduce product temperature. If in
doubt always consult the
manufacturer.
Reduce operating pressure. If in doubt
always consult the manufacturer.
Check the suction conditions. If in
doubt always consult the
manufacturer.
Check rollers shaft mounting.
Consult the manufacturer
Lubricate hose with original lubricant.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GREEN INSTRUMENTS Maritime G6100 and is the answer not in the manual?

GREEN INSTRUMENTS Maritime G6100 Specifications

General IconGeneral
BrandGREEN INSTRUMENTS
ModelMaritime G6100
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals