GREENWORKSTOOLS.COM GREENWORKSCOMMERCIAL.COM
13
2021-03-18
2.4. FINDING A BREAK IN THE BOUNDARY LOOP
If a guide wire is used, a break in the boundary loop wire can be found
as follows:
Connect the charging station to the power supply.
Switch the left ( ) boundary loop connector and the guide wire
(G) connector.
If the LED flashes blue, the break is somewhere in the boundary
loop wire between the left ( ) boundary loop connector and the
position where the guide wire is connected to the boundary
loop wire.
Put the connections back in their original positions.
Switch the right ( ) boundary loop connector and guide wire (G)
connector.
If the LED flashes blue, the break is somewhere in the boundary
loop wire between the right ( ) boundary loop connector and the
position where the guide wire is connected to the boundary
loop wire.
1
2
3
4
5
6
Put the connections back in their original positions.
When the break is found, replace the damaged section with a
new loop wire.
Note: Use only original couplers.
7
8