AC output/input data
Rated output/input power 6000/6000W
Rated output apparent power 6000VA
Nominal voltage 230 a.c.V
Rated input / output current
27/27 a.c.A
Nominal Frequency 50Hz
Power factor range 0.8leading~0.8lagging
Stand alone data
Rated output apparent power 4000VA
Nominal voltage 230 a.c.V
Rated output current 17.5 a.c.A
Nominal Frequency 50 Hz
Power factor range 0.8leading~0.8lagging
Battery data
Battery voltage range 42~59 d.c.V
Rated charging and
discharging current
85 d.c.A
Type of Battery Lithium/Lead-acid
other
Safety level Class I
Overvoltage category PV:II AC:III Others:I
Ingress protection IP65
Operation Ambient Temperature
-25℃~+60℃
Inverter topology Non-isolated
Certificate No SAAXXX

Other manuals for Growatt SPH4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH4000 and is the answer not in the manual?

Growatt SPH4000 Specifications

General IconGeneral
ModelSPH4000
CategoryInverter
Rated Power4000 W
Max. DC Voltage550 V
MPPT Voltage Range120 V - 500 V
Number of MPPTs2
AC Output Voltage230 V
Frequency50/60Hz
Efficiency97.5%
Start Voltage150 V
Nominal DC Voltage360V
Max. Input Current per MPPT11 A
AC Nominal Power4000 W
Max. AC Apparent Power4000 VA
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging
THDi<3%
AC Connection TypeSingle phase
Max. Charge/Discharge Power4000 W
Nominal Battery Voltage48 V
Communication with BMSCAN/RS485
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
TopologyTransformerless
Weight25 kg
Max. PV Input Voltage550 V
Cooling MethodNatural Convection