very seldom equal to the direct product of the volts and amperes. In order to find the power of a
single phase ac circuit the product of volts and amperes must be multiplied by the power factor.
PV
Abbreviation for photovoltaic
BAT
BAT is an acronym for lithium or lead acid battery
Charging
An SPH hybrid inverter charger uses PV energy or grid energy to charge a battery
Discharging
It means that the SPH hybrid inverter supplies the battery energy to the load
wireless communication
The external wireless communication technology is a radio technology that allows the inverter and
other communication products to communicate with each other. The external wireless
communication does not require line of sight between the devices and it is selective purchasing.
1.4 Product Description
SPH Series is used to store energy generated by the photovoltaic cell panels or energy from grid if it is
allowed in the battery, also energy can be sent to power grid through SPH for self consumption or when Grid
power is lost, SPH can be used as backup power.
SPH series has six kinds of type:
Growatt SPH3000.
Growatt SPH3600.
Growatt SPH4000.
Growatt SPH4600.
Growatt SPH5000.
Growatt SPH6000.
SPH 3000TL BL-UP
SPH 3600 TL BL-UP
SPH 4000TL BL-UP
SPH 4600TL BL-UP
SPH 5000TL BL-UP
SPH 6000TL BL-UP
Note: We describe this series as “SPH” as below.
Note:
In different country, we provide different power. Such as in Germany, we can provide SPH 3000~SPH
4600TL BL-UP& Growatt SPH3000~ Growatt SPH4600, but we don’t provide SPH 5000TL BL-UP (Growatt
SPH5000 )and SPH 6000TL BL-UP(Growatt SPH6000).
Overview:

Other manuals for Growatt SPH4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH4000 and is the answer not in the manual?

Growatt SPH4000 Specifications

General IconGeneral
ModelSPH4000
CategoryInverter
Rated Power4000 W
Max. DC Voltage550 V
MPPT Voltage Range120 V - 500 V
Number of MPPTs2
AC Output Voltage230 V
Frequency50/60Hz
Efficiency97.5%
Start Voltage150 V
Nominal DC Voltage360V
Max. Input Current per MPPT11 A
AC Nominal Power4000 W
Max. AC Apparent Power4000 VA
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging
THDi<3%
AC Connection TypeSingle phase
Max. Charge/Discharge Power4000 W
Nominal Battery Voltage48 V
Communication with BMSCAN/RS485
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
TopologyTransformerless
Weight25 kg
Max. PV Input Voltage550 V
Cooling MethodNatural Convection