EasyManuals Logo

Growatt SPH4000 Installation Manual

Growatt SPH4000
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
logistical and process costs incurred by all parties in relation to this warranty claim.
11 Decommissioning
11.1 Dismantling the energy storage
1. Disconnect the storage machine such as mentioned in section 7
2. Disconnect the upper cable of SPH inverter
Watch out the SPHs shell heat and prevent to scald
Wait 20 minutes until the SPH cooling and then to disassembly!
3. Unscrew all the connecting cable
4. Unscrew the radiator and wall-mounted anchor screw and then take down the machine from wall.
11.2 Packing the SPH inverter
Usually placed SPH inverter in the packing box with tape sealing, if the SPH inverter cannot reoccupy, you can
choose a cheap carton for packaging. Carton requirements must meet the size of the inverter and can support
energy storage machine overall weight.
11.3 Storing SPH inverter
Store SPH inverter in a dry place where ambient temperatures are always between -25°C and +60°C
11.4 Disposing of the SPH inverter
Do not dispose of SPH inverter together with household waste. Please accordance with the
disposal regulations for electronic waste which apply at the installation site at that time.
Ensure that the old unit and, where applicable, any accessories are disposed of in a proper
manner
12 Product specification
12.1 SPH series energy storage machine product specification
Model
Specifications
Growatt
SPH3000&SP
H 3000TL
BL-UP
Growatt
SPH3600
&SPH
3600TL BL-UP
Growatt
SPH4000
&SPH
4000TL BL-UP
Growatt
SPH4600
&SPH
4600TL BL-UP
Growatt
SPH5000
&SPH
5000TL BL-UP
Growatt
SPH6000&SPH
6000TL BL-UP
备注
Input data(DC)
Max.
6000W 7200W 7200W 8000W 8000W 9000W

Other manuals for Growatt SPH4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH4000 and is the answer not in the manual?

Growatt SPH4000 Specifications

General IconGeneral
ModelSPH4000
CategoryInverter
Rated Power4000 W
Max. DC Voltage550 V
MPPT Voltage Range120 V - 500 V
Number of MPPTs2
AC Output Voltage230 V
Frequency50/60Hz
Efficiency97.5%
Start Voltage150 V
Nominal DC Voltage360V
Max. Input Current per MPPT11 A
AC Nominal Power4000 W
Max. AC Apparent Power4000 VA
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging
THDi<3%
AC Connection TypeSingle phase
Max. Charge/Discharge Power4000 W
Nominal Battery Voltage48 V
Communication with BMSCAN/RS485
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
TopologyTransformerless
Weight25 kg
Max. PV Input Voltage550 V
Cooling MethodNatural Convection

Related product manuals