Chart 6.13
Note:
USB is only used for firmware update. Customer can’t use it for charging.
6.5.2 The SPH’s monitoring
The SPH provide RS232 interface. Users can through the following communication solution to monitor the SPH.
Note:
This kind of monitoring can only be used by the monitor of Growatt’s Shineserver /shine phone provided by
the company. Through RS232 interface connect to Wi-Fi-S/shinelink, use computer terminal/or mobile phone
for data monitoring.
Chart 6.17
Before use WIFI communication, you should make sure the follow PIN1 and PIN2 are ON:

Other manuals for Growatt SPH4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPH4000 and is the answer not in the manual?

Growatt SPH4000 Specifications

General IconGeneral
ModelSPH4000
CategoryInverter
Rated Power4000 W
Max. DC Voltage550 V
MPPT Voltage Range120 V - 500 V
Number of MPPTs2
AC Output Voltage230 V
Frequency50/60Hz
Efficiency97.5%
Start Voltage150 V
Nominal DC Voltage360V
Max. Input Current per MPPT11 A
AC Nominal Power4000 W
Max. AC Apparent Power4000 VA
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging
THDi<3%
AC Connection TypeSingle phase
Max. Charge/Discharge Power4000 W
Nominal Battery Voltage48 V
Communication with BMSCAN/RS485
Operating Temperature Range-25°C to +60°C
Protection DegreeIP65
TopologyTransformerless
Weight25 kg
Max. PV Input Voltage550 V