11. Disassembly
Before disassembling the pump:
Switch off the power supply
Close the isolating valves, if fitted, to avoid draining the pipe system.
Disconnect the power supply cable from the pump.
Note the pump's centre of gravity to prevent it from turning or rolling over.
11.1 Remove the motor top cover
1. Remove the screws (183) from the upper part of the cable inlet (168).
183
168
157D
TM084194
2. Remove the upper part of the cable inlet (168).
3. Remove the screws holding the motor top to the stator housing (67).
67
164
62
TM084092
4. Attach the lifting equipment to the designated lifting points (lifting handle) lift the motor top off.