15. Ground continuity test
Check the ground continuity between the user end of power cable ground wire and the metal housing. Repeat the test with the same
parameters two times.
1. Use lifting handle as metal housing point.
2. Use any of the screws highlighted as a metal housing point.
2
1
TM084629
Cable length must be compensated for if it is longer than 10 meters. (Cable resistance: 0.5 - 1.78 mΩ/m). In case of dual cable, parallel PE
connection is to be used.
Test duration
5 [sec]
Test voltage 12 [V]
Nominal current 10 [A]
Min. test current 9.6 [A]
Max. test current 10.4 [A]
Min. resistance 0.004 [Ω]
Max. resistance 0.25 [Ω]