12.2 NDE bearing mount
1. Heat up the NDE bearing (154) to 90-110 °C. Use an induction heater or hot air blower gun.
2. Press the bearing down on the end of the shaft with rotor assembly (172).
154
TM084262
Correct position of NDE bearing
WARNING
Hot surface
Death or serious personal injury
Do not touch the heated parts surfaces. Wear
protective clothing.