12.14 Mounting the motor on the pump housing
1. Grease and mount the O-ring (39B) on the lower seal housing groove of the motor.
B
39B
C
67B
67
A
TM084500
A Motor housing
B Hydraulics
C Alignment grooves
2. Place at least three lifting eyes into the threaded holes marked below.
TM084552
3. Lift the motor and place it on the pump housing.
78