12.9 Mounting the assembled upper seal housing
1. Lift and mount the upper seal housing on the stator housing. Do not use the three marked threaded hole for lifting! The fixing screw of the
lower bearing bracket will help to properly orientate the upper seal housing.
67
404
58
TM084259
2. Insert the screws (67) and bonded washers (404).
3. Tighten the screws (67) to the required torque. Tightening sequence:
4
6
2
7
3
5
1
8
TM084495
Related information
7. Tightening torques and lubricants