3. Heat up the stator housing (55). If possible, use a furnace to ensure even heating.
WARNING
Hot surface
Death or serious personal
injury
Do not touch the
heated parts surfaces.
Wear protective
clothing.
T1
T2
TM084261
T1
External surface temperature. Must not exceed 210 °C and must be maintained for a maximum of
15 minutes.
T2 Internal surface temperature. 210 °C during stator insertion.
4. After stator insertion, wait until the stator housing cools down to room temperature, then perform insulation resistance and sensor tests
according to the following:
Insulation resistance measurement points
Between stator phase leads and the stator housing
U1+U2+V1+V2+W1+W2 - Stator housing
Between stator phase leads and stator ground wire U1+U2+V1+V2+W1+W2 - PE
Insulation resistance test parameters
Duration:
60 seconds
Voltage: 1000 V
Voltage upper limit: 1020 V
Voltage lower limit: 980 V
Min. resistance: 1000 mΩ
Max. resistance: 20000 mΩ
Sensor and switch test
Thermal protectors (PTO) continuity test
Terminals: 2TB1-2TB2
Resistance: < 320 mΩ
Thermistors (PTC) continuity test
Terminals: 2TP1-2TP2
Resistance: < 750 mΩ