7. Insert the screws (183) into the upper bearing bracket and tighten them to the required torque.
8. Pull the power leads through the cable glands (28).
B
A
O
TM084607
A Sensor wires
B Power wires
O Correct orientation
9. Pull the sensor wires through their separate cable gland.
10. Mount the cable glands, check that they are in the proper position, and tighten them to the required torque.
11. Insert the screw (89) and brass washer on the threaded hole in the middle of the upper bearing bracket.