4. Fasten the upper cable entry (168) and tighten the lower cable entry (168A). Follow the distances from the striped cable end according to
the image below.
Screened cable version Standard cable version
181S 181B
(160,5)
82,5
122
2
+
-
(200)
2
+
-
TM084506
181S 181B
82,5
2
+
-
122
2
+
-
(200)
TM084507
5. Pull the motor end of the preassembled cables through the corresponding holes of the motor top (164A)
6. Mount the lifting handle (190) on the motor top (164A) with screws (67) and washers (67B).
7. Tighten the screws with the required torque.
TM084508
Related information
7. Tightening torques and lubricants
8.2.1 Standard sensor version
8.2.2 Sensor version V1
8.2.3 Sensor version V2
83