5. Mount the earth wire of the power cables to the the bracket for wire termination (522) with serrated lock washer (230B), spring lock washer
(89A) and screw (1) according to the image below.
1
89A
407
230B
TM084093
Each power cable's earthing wire has got a dedicated place on the bracket for wire termination (522), on the opposite side of the cable.
6. Pull the sensor cable bullet onto the bullet holder on the bracket for wire termination (522) with the screws (93) to fix the sensor cable. The
bullet must be positioned next to the sensor terminal board (176).
7. Mount the cable clamps (409) on the bracket for wire termination (522) with the screws (93) to fix the sensor cable in place.
8. Tighten the screws (93) to the required torque.
9. Lead the sensor cable cores behind the leg of the bracket for wire termination (522) and connect the wires to the sensor terminal board
(176), according to the connection diagram.
10. Secure the sensor wires to the bracket for wire termination (522) with cable ties.
Related information
7. Tightening torques and lubricants
8.2.1 Standard sensor version
8.2.2 Sensor version V1
8.2.3 Sensor version V2
85
English (GB)