GTO 3000XLS/3200XLS Instruction Manual © 01.10.12 23
Input Connections
• Allcontrolinputsaredry-contact,normallyopen,inputs.DONOTapplyexternalvoltagesourcesto
these inputs.
• AllinputsareconnectedwithrespecttoCOMMONterminal.
• ThestatusLEDwillblinkoncewhenitscorrespondinginputisactivated.
1 COM: Circuit common (reference for all
logic input)
•Two(2)terminalstoprovideextra
common connection point.
2 CYCLE/CLOSE: (Typically for use with
push button or hard-wired keypad)
• Eachactivationatthisinputwillcycle
the operation as follows:
OPEN–STOP–CLOSE–STOPOPEN
3 SAFETY: (Typically for use with photo
beam device, loop detector or other
non-contact sensors)
• Activationofthisinputwhilethegate
is closing will cause the gate to stop
and return to the opened position.
• Activationofthisinputwhilethegate
is opening has no eect (gate will
continue to open).
• Activationofthisinputwhilegateis
idle will prevent gate from closing.
4 EXIT/OPEN: (Typically for use with exit
loop or wand)
• Activationofthisinputwillopenthe
gateifit’snotalreadyattheopen
position.
• Activationofthisinputwhileatopen
limit will restart the auto close time (if
enabled).
• Activationofthisinputwhilegateisidlewillpreventgatefromclosing.
5 SHADOW LOOP: (Typically for use with loop detector)
• Thisinputisonlymonitoredwhenthegateisatthefullyopenposition.Atanyotherposition,
activation of this input has no eect on gate operation.
• Activationofthisinputwhilegateatthefullyopenpositionwillpreventgatefromclosing.
6 CLOSE EDGE: (Typically for use with safety edge device)
• Activationofthisinputwhilethegateisclosingwillcausethegatetostopandreversedirectionfor
approximately 2 seconds.
• Activationofthisinputwhilethegateisopeninghasnoeect(gatewillcontinuetoopen).
• Activationofthisinputwhilegateisidlewillpreventgatefromclosing.
7 OPEN EDGE: (Typically for use with safety edge device)
• Activationofthisinputwhilethegateisopeningwillcausethegatetostopandreversedirection
for approximately 2 seconds.
• Activationofthisinputwhilethegateisclosinghasnoeect(gatewillcontinuetoclose).
• Activationofthisinputwhilegateisidlewillpreventgatefromopening.
Connecting Accessories
GRNCOM COM
CYCLE
CLOSE
SAFETY
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
RECEIVER
ALM
CONTROL INPUTS
1
2
3
4
7
5
6