MEASUREMENT
43
Compare function
indicator
Measured value as a
percentage of the
reference value
Measured value
Reference, limits, compare
mode and beep mode
Pass/Fail judgment
A measured value that falls within the upper and lower
limits is considered IN (pass), a value that falls below the
lower limits is considered LO, and a value that falls over
the upper limit is a HI.
Reference
value
Upper
limit
Lower
limit
IN HILO
%
%
For all the compare modes, IN, HI or LO will be shown
on the display for each judgment.
1. Select the
compare function
Press
Compare
to access the compare mode, as shown
above.
2. Select the
compare mode
Use the arrow keys to navigate to the Mode setting. Press
the Enter key to toggle the compare mode.
Mode
Move
Toggle
Enter
Range
Abs, %, %