PSU Series Programming Manual
116
:SYSTem:CONFigure:TRIGger:INPut:WIDTh
Set
Query
Description
Sets or queries the input trigger pulse width. A
setting of 0 indicates that the input trigger is
controlled by the trigger input level, rather than a
trigger pulse.
Syntax
Return Syntax
:SYSTem:CONFigure:TRIGger:INPut:WIDTh
{<NR2>|MINimum|MAXimum}
:SYSTem:CONFigure:TRIGger:INPut:WIDTh?
[MINimum|MAXimum]
Parameter
<NR2>
0 ~ 60ms.
MINimum
Minimum width = 0.
MAXimum
60ms
Return Parameter
<NR2>
Returns the trigger input width.
:SYSTem:CONFigure:TRIGger:OUTPut:SOURce
Set
Query
Description
Sets or queries the output trigger source.
Syntax
Return Syntax
:SYSTem:CONFigure:TRIGger:OUTPut:SOURce
{<NR1>|NONE|OUTPut|SETTing|MEMory}
:SYSTem:CONFigure:TRIGger:OUTPut:SOURce?
Parameter
NONE | 0
No output trigger.
OUTPut | 1
Output trigger is generated by a
change in the output.
SETTing | 2
Output trigger is generated when a
setting is changed.
MEMory | 3
Output trigger is generated when a
memory setting is loaded.
Return Parameter
<NR1>
Returns the output source.

Table of Contents