162
PSU Factory Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
1.1 X Vrate
OCP
1.1 X Irate
Normal Function
Settings
Setting
Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time
F-02
0.00s
V-I mode slew rate select
F-03
0 = CV high speed priority
Internal resistance
setting
F-08
0.000
Bleeder circuit control
F-09
1 = ON
Buzzer ON/OFF control
F-10
1 = ON
OCP Delay Time
F-12
0.1 (seconds)
Current Setting Limit
F-13
0 = OFF
Voltage Setting Limit
F-14
0 = OFF
Display Memory
parameter when recalling
F-15
0 = OFF
Auto parallel Control
F-16
0 = OFF
Measurement Average
Setting
F-17
0 = Low
Alarm Recovery and
Output Status
F-18
0 = Safe Mode
Lock Mode
F-19
0:Lock Panel, Allow Output OFF
USB / GPIB setting
Setting
Default Setting
Setup Rear USB Speed
F-22
2 = Auto detect
GPIB address
F-23
8
GPIB Enable/Disable
F-24
1 = Enable
SCPI Emulation
F-26
0 = GW Instek
LAN setting
Setting
Default Setting
LAN
F-36
1 = Enable
DHCP
F-37
1 = Enable

Table of Contents

Other manuals for GW Instek PSU 100-15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU 100-15 and is the answer not in the manual?

GW Instek PSU 100-15 Specifications

General IconGeneral
BrandGW Instek
ModelPSU 100-15
CategoryPower Supply
LanguageEnglish

Related product manuals