H3C S5560S-SI Series - Garbled Display on the Configuration Terminal

H3C S5560S-SI Series
51 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
Solution
To resolve the issue:
1. Verify that the power system is operating correctly.
2. Verify that the switch is operating correctly.
3. Verify that the console cable has been connected correctly.
4. Verify that the following settings are configured for the terminal:
Baud rate9600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
5. Verify that the console cable is not faulty.
6. If the issue persists, contact H3C Support.
Garbled display on the configuration terminal
Symptom
The configuration terminal displays garbled text.
Solution
To resolve the issue:
1. Verify that the following settings are configured for the terminal:
Baud rate9600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
2. If the issue persists, contact H3C Support.