98
Restrictions and guidelines
The LSI-9540 or 9560 series storage controller supports migration or expansion in UEFI mode or in
the OS only in RAID 0, 1, 5, or 6.
A storage controller does not support simultaneously reconfiguring two RAID arrays, which involves
reconfiguring virtual drives, including drive expansion or RAID level migration. You must reconfigure
a RAID array one by one.
A newly added drive must be of the same type as the member drives in a RAID array, and its
capacity cannot be smaller than the minimum capacity of the member drives in the RAID array.
For expansion with new drives, RAID 1 requires adding 2*N drives each time, and RAID 0, 1, 5, or 6
supports a maximum of 32 member drives.
Procedure
1. On the storage controller configuration screen as shown in Figure 173, select Virtual Drive
Management and press Enter.
Figure 173 Storage controller configuration screen
2. On the screen as shown in Figure 174, select the target logical drive and press Enter.